Prior to Installation
Please read and understand all cautions, warnings, instructions, and product labels before installing linear light, otherwise, it could result in injury and void the warranty.
Warning
- Luminaires are suitable for direct mounting on normally flammable surfaces.
- Disconnect power before installing or servicing. This lighting fixture must be installed, connected and tested by a qualified electrician.
- Please check local voltage in accordance with the product requirements before using the product.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- The power cord please choose H07RN-F 3×1.5mm2.
- The terminal box shall be approved according to EN 60998-2-1 or EN 60998-2-2; and shall comply with below specification: the type of terminal (screw/screwless); number of terminals; (2 terminals for L/N connecting); rated voltage (>450 V); rated connecting capacity; (0.75-2.5mm2) the wire end must clamped by crimp terminal wire connector to prevent the free wire of conductor escaping; the terminal block must be protected against of electric shock; fixing the terminal block by glue; Connect up the red wire to ‘L’ terminal, and blue wire connected to ‘N’ terminal.
- The max distance between two suspension kits or surface mounted kits is adjustable, 3m maximum.
- The installation height is 15m maximum with 100lux.
- The electric current of each single wire and connector is 16A.